| Type | Cyclone filter |
|---|---|
| Application | Install it in the coolant circuit of the machine tool. |
| Features |
・For a low pressure drop, It restrains a temperature rise of coolant. ・For high filtration precision, It maintains the processing precision of the machine tool. ・Enhance durability, and prolong service. |
| Item | Standard Spec. | Option |
|---|---|---|
| Corresponding fluid | Water-soluble coolant etc. | |
| Maximum working pressure | 1.0MPa | 0.4MPa (Installation sludge tank) |
| Working temp range | 0~60℃ | |
| Working kinematic viscosity range | ~2.5mm2/s | |
| Working flow rate range | MCS-06-1: 30~50L/min MCS-06-2: 30~60L/min MCS-06-2L:20~40L/min MCS-08-K/V:60~120L/min MCS-12K/V:120~200L/min |
MCS-08-S150/S200: 60~110L/min MCS-12-S150/S200: 120~170L/min (Installation sludge tank) |
| Drain valve | n/a | Installation optional |
| Sludge tank | n/a | Installation optional (with drain valve) |
| Bracket | Installation optional (only MCS-06) |
| Code | Seal material |
| - | NBR |
| F | FKM |
| Code | Inner diameter | |
| 06 | IN:Rc3/4 | |
| OUT:Rc1 | ||
| DRAIN:R3/4 | ||
| Code | Inner diameter | Working flow rate *2 |
| 08 | IN:Rc1 | 60~120L/min |
| OUT:Rc1 | ||
| DRAIN:R1 | ||
| 12 | IN:Rc1 1/2 | 120~200L/min |
| OUT:Rc1 1/2 | ||
| DRAIN:R1 1/2 | ||
| Code | Working flow rate |
| 1 | 30~50L/min |
| 2 | 30~60L/min |
| 2L | 20~40L/min |
| Only MCS-06 | |
| Code | Drain type |
| K | n/a |
| V | Drain valve |
| S | Drain valve, sludge tank(420㎤), With Drain valve |
| MCS-06 | |
| Code | Drain type |
| K | n/a |
| V | Drain valve |
| S150 | Drain valve, sludge tank(1050㎤), With Drain valve |
| S200 | Drain valve, sludge tank(1400㎤), With Drain valve |
| MCS-08, 12 | |
| Code | Bracket |
| K | n/a |
| B |
Bracket |
| Only MCS-06 | |
*1 Only with sludge tank is selectable.
*2 For flow rate with sludge tank, refer to the table above.
- Precautions for use -
* Cannot be used in frozen state.
* Please note that the performance may not be fully demonstrated if used with a small flow
rate or a high viscosity liquid.
Please note that the filtration efficiency will decrease especially when the pump is
started or stopped.
* Do not install the sludge tank where there is a possibility of visible vibration.
Model example 1:MCS-06-2-VB
Model example 2:MCS-12-S200
+81-3-6912-9922+81-3-6912-9922
Excluding Saturdays, Sundays and Holidays