| Type | Return line filter |
|---|---|
| Application | The TRF-A is installed on the return line of the reservoir tank just before the reservoir tank to prevent contaminants from entering the tank. |
| Features |
・By using CFD(fluid numerical analysis), achieved low pressure drop and large flow rate. ・Installed directly on top of a tank. ・Newly added set element for high flow type. ・Pressure gage or pressure switch is available in additional option. |
| Item | Standard Spec. | Option |
|---|---|---|
| Corresponding fluid | Mineral oil | Phosphate ester oil, water glycol oil |
| Maximum working pressure | 0-1MPa | - |
| Indicator | n/a | Select from Pressure gage, pressure switch |
| Relief valve (Bypass) | n/a | Installation optional |
| Connection | Rc threaded type | Can be modified with an optional weld flange type |
| Magnet | n/a | - |
| Code | Fluid type |
| - | Mineral oil |
| F | Phosphate ester oil |
| G | Water glycol oil |
| Code | Inner diameter |
| 06A | Rc3/4 (20A) |
| 08A | Rc1 (25A) |
| 10A | Rc1-1/4 (32A) |
| 12A | Rc1-1/2 (40A) |
| Code | Filtration |
| C-Fiber | |
| 3C | 3μm |
| 8C | 8μm |
| 25C | 25μm |
| Paper (High flow) | |
| 10UF*2 | 10μm |
| 20UF*2 | 20μm |
| Paper | |
| 10U | 10μm |
| 20U*2 | 20μm |
| 40U*2 | 40μm |
| Wire gauze | |
| 5UW | 5μm |
| 10UW | 10μm |
| 20UW | 20μm |
| 40UW | 40μm |
| 50UW | 50μm |
| 200W | 200Mesh |
| 150W | 150Mesh |
| 100W | 100Mesh |
| 60W | 60Mesh |
| (1) | Indicator | |
| - | Plug | |
| I | Pressure gauge | |
| E | Pressure switch | |
| (2) | Relief valve (Bypass) | |
| K | n/a | |
| V | Attached | |
| (3) | Companion flange | |
| - | n/a | |
| N | Attached | |
| Code | Fluid type |
| - | Mineral oil |
| F | Phosphate ester oil |
| G | Water glycol oil |
| Code | Inner diameter |
| 06A | Rc3/4 (20A) |
| 08A | Rc1 (25A) |
| 10A | Rc1-1/4 (32A) |
| 12A | Rc1-1/2 (40A) |
| Code | Filtration |
| C-Fiber | |
| 3C | 3μm |
| 8C | 8μm |
| 25C | 25μm |
| Paper (High flow) | |
| 10UF*2 | 10μm |
| 20UF*2 | 20μm |
| Paper | |
| 10U | 10μm |
| 20U*2 | 20μm |
| 40U*2 | 40μm |
| Wire gauze | |
| 5UW | 5μm |
| 10UW | 10μm |
| 20UW | 20μm |
| 40UW | 40μm |
| 50UW | 50μm |
| 200W | 200Mesh |
| 150W | 150Mesh |
| 100W | 100Mesh |
| 60W | 60Mesh |
| Code | Sealing parts set |
| SP |
For element replacement |
| SA | For overhaul |
| Code | Fluid type |
| - | Mineral oil |
| F | Phosphate ester oil |
| G | Water glycol oil |
| Code | Inner diameter |
| 06A | Rc3/4 (20A) |
| 08A | Rc1 (25A) |
| 10A | Rc1-1/4 (32A) |
| 12A | Rc1-1/2 (40A) |
| Code | Companion flange |
| - | n/a |
| N | Attached |
*1 For fluids other than the above fluids. Please ask us for details.
*2 20U and 40U are not available for water glycol oil.
Filter Model example:TRF-08A-10U-V
Element Model example:P-TRF-08A-10U
Seals Model example:SA-TRF-08A
■ Model code of replacement element consists of two types: ”Individual code” and "Common code", however it represents same product.
”Individual code” :Used in drawings and nameplate.
Model example:P-TRF-08A-10U
"Common code" :Used in vouchers and tag.
Model example:P-TRF,TRA,TLA-06,08-10U
+81-3-6912-9922+81-3-6912-9922
Excluding Saturdays, Sundays and Holidays