| Type | Line filter |
|---|---|
| Application | The line filter is installed in-line to maintain the oil purity level in the hydraulic piping and protect hydraulic equipment from contaminants. |
| Features |
・Downward extraction type element. ・Select from many options like indicators, relief valve, etc. ・Choose from 4 types of element lengths for all inner diameters. ・Element common to GC type filters. |
| Item | Standard Spec. | Option |
|---|---|---|
| Corresponding fluid | Mineral oil | Phosphate ester oil, water glycol oil |
| Maximum working pressure | 0-35MPa | - |
| Indicator | n/a | Select from visual type, electric contact type, and electric contact type (micro capacity) |
| Relief valve (Bypass) | n/a | Installation optional |
| Connection | G threaded type | Can be modified with an optional weld flange type |
| Magnet | - | - |
| Code | Fluid type |
| - | Mineral oil |
| F | Phosphate ester oil |
| G | Water glycol oil |
| Code | Inner diameter |
| 08Z | G1 (25A) |
|
10Z (Discontinued product) |
G1 1/4 (32A) |
| 12Z | G1 1/2 (40A) |
| Code |
| 3 |
|
4 (Discontinued product) |
| 5 |
| 6 |
| Code | Filtration |
| C-Fiber | |
| 3C | 3μm |
| 8C | 8μm |
| 25C | 25μm |
| C-Fiber (High pressure) | |
| 3CH | 3μm |
| 8CH | 8μm |
| 25CH | 25μm |
| Paper | |
| 10U | 10μm |
| 20U*2 | 20μm |
| 40U*2 | 40μm |
| Wire gauze | |
| 5UW | 5μm |
| 10UW | 10μm |
| 20UW | 20μm |
| 40UW | 40μm |
| 50UW | 50μm |
| 200W | 200mesh |
| 150W | 150mesh |
| 100W | 100mesh |
| 60W | 60mesh |
| (1) | Indicator |
| - | Plug |
| I | Visual type |
| E | Electric contact type |
| D | Electric contact type (micro capacity) |
| (2) | Relief valve (Bypass) *3 |
| V | Attached |
| K | n/a |
| (3) | Companion flange |
| - | n/a |
| N | Attached |
| Code | Fluid type |
| - | Mineral oil |
| F | Phosphate ester oil |
| G | Water glycol oil |
| Code |
| 3 |
| 4 |
| 5 |
| 6 |
| Code | Filtration |
| C-Fiber | |
| 3C | 3μm |
| 8C | 8μm |
| 25C | 25μm |
| C-Fiber (High pressure) | |
| 3CH | 3μm |
| 8CH | 8μm |
| 25CH | 25μm |
| Paper | |
| 10U | 10μm |
| 20U*2 | 20μm |
| 40U*2 | 40μm |
| Wire gauze | |
| 5UW | 5μm |
| 10UW | 10μm |
| 20UW | 20μm |
| 40UW | 40μm |
| 50UW | 50μm |
| 200W | 200mesh |
| 150W | 150mesh |
| 100W | 100mesh |
| 60W | 60mesh |
| Code | Sealing parts set |
| SP |
For element replacement |
| SA | For overhaul |
| Code | Fluid type |
| - | Mineral oil |
| F | Phosphate ester oil |
| G | Water glycol oil |
| Code | Inner diameter |
| 08Z | G1 (25A) |
| 10Z | G1 1/4 (32A) |
| 12Z | G1 1/2 (40A) |
| Code | Filtation rating |
| 無 | All mdels except bellow |
| H | 3CH, 8CH, 25CH |
| HW | 5UW, 10UW, 20UW |
| Code | Companion flange |
| - | n/a |
| N | Attached |
*1 For fluids other than the above fluids. Please ask us for details.
*2 20U and 40U are not available for water glycol oil.
*3 Relief valve is not available if selecting high pressure element.
Filter Model example:F-SH-08Z-5-3CH-EKN
Element Model example:P-F-SH-5-3CH
Seals Model example:SA-F-SH-08Z-HN
■ Model code of replacement element consists of two types: ”Individual code” and "Common code", however it represents same product.
”Individual code” :Used in drawings and nameplate.
Model example:P-F-SH-5-3CH
"Common code" :Used in vouchers and tag.
Model example:P-F-GC,SH,4201-5-3CH
+81-3-6912-9922+81-3-6912-9922
Excluding Saturdays, Sundays and Holidays