Oil Filters List

TM

TM
Type

Line filter

Application

The line filter is installed in-line to maintain the oil purity level in the hydraulic piping and protect hydraulic equipment from contaminants.

Features

・Downward extraction type element.

・Select from many options like indicators, relief valve, etc.

・Choose from 2 types of element lengths for all inner diameters.

・Element common to GM type filters.

Download

Specifiations

Item Standard Spec. Option
Corresponding fluid Mineral oil Phosphate ester oil, water glycol oil
Maximum working pressure 0-21MPa -
Indicator n/a Select from visual type, electric contact type, and electric contact type (micro capacity)
Relief valve (Bypass) n/a Installation optional
Connection Rc threaded type -
Magnet n/a -

ItemsModel

Fluid type*1

Code Fluid type
- Mineral oil
F Phosphate ester oil
G

Water glycol oil

TM

C

Inner diameter

Code Inner diameter
04 Rc1/2

06

(Discontinued product)

Rc3/4

Case length

Code
2
3

Filtration

Code Filtration
C-Fiber
3C 3μm
8C 8μm
25C 25μm
 C-Fiber (High pressure)
3CH 3μm
8CH 8μm
25CH 25μm
Paper
10U 10μm
20U*2 20μm
40U*2 40μm
Wire gauze
5UW 5μm
10UW 10μm
20UW 20μm
40UW 40μm
50UW 50μm
200W 200mesh
150W 150mesh
100W 100mesh
60W 60mesh

 

Option(1)(2)

(1) Indicator
- Plug
I Visual type
E Electric contact type
D Electric contact type (micro capacity)
(2) Relief valve (Bypass) *3
V Attached
K n/a

P

Fluid type*1

Code Fluid type
- Mineral oil
F Phosphate ester oil
G

Water glycol oil

TM

Case length

Code
2
3

Filtration

Code Filtration
C-Fiber
3C 3μm
8C 8μm
25C 25μm
 C-Fiber (High pressure)
3CH 3μm
8CH 8μm
25CH 25μm
Paper
10U 10μm
20U※3 20μm
40U※3 40μm
Wire gauze
5UW 5μm
10UW 10μm
20UW 20μm
40UW 40μm
50UW 50μm
200W 200 mesh
150W 150 mesh
100W 100 mesh
60W 60 mesh

 

Set type

Code Sealing parts set
SP

For element

replacement

SA For overhaul

Fluid type*1

Code Fluid type
- Mineral oil
F Phosphate ester oil
G

Water glycol oil

TM-C

Inner diameter

Code Inner diameter
04 Rc1/2
06 Rc3/4

*1 For fluids other than the above fluids. Please ask us for details.

*2 20U and 40U are not available for water glycol oil.

*3 Relief valve is not available if selecting high pressure element.

Filter Model example:F-TM-C-04-2-3C-IV

Element Model example:P-F-TM-2-3C

Seals  Model example:SA-TM-C-04

 

■ Model code of replacement element consists of two types: ”Individual code” and "Common code", however it represents same product.

”Individual code” :Used in drawings and nameplate.

  Model example:P-F-TM-2-3C

"Common code" :Used in vouchers and tag.

  Model example:P-F-TM,GM-2-3C

 

Contact

Please login, and you will send selection request.