| Type | Case type suction filter |
|---|---|
| Application | This filter protects the hydraulic pump by preventing the circulation of line contamination from the reservoir tank. |
| Features |
・Signature case type suction filter model. ・An abundant line up of upward extraction type elements with a substantial range of sizes (inner diameter 10A-150A) and a variety of options makes element replacement easy. *125A and 150A are available. (built to order) ・The shape of the case prevents air accumulation within the case. |
| Item | Standard Spec. | Option |
|---|---|---|
| Corresponding fluid | Mineral oil | Phosphate ester oil, water glycol oil |
| Maximum working pressure | -0.1-0.5MPa | - |
| Indicator | Visual type | Select from electric contact type, electric contact type (micro capacity) |
| Relief valve (Bypass) | Equipped | |
| Connection | Weld flange type | Can modify with Rc threaded flange type |
| Magnet | n/a | Installation optional |
| Code | Fluid type |
| - | Mineral oil |
| F | Phosphate ester oil |
| G | Water glycol oil |
| Code | Inner diameter |
| 03A | 10A |
| 04A | 15A |
| 06A | 20A |
| 08A | 25A |
| 10A | 32A |
| 12A | 40A |
| 16A | 50A |
| 20B | 65A |
| 24B | 80A |
| 28A | 90A |
| 32A | 100A |
| Code | Filtration |
| Wire gauze | |
| 60W | 60Mesh |
| 100W | 100Mesh |
| 150W | 150Mesh |
| 200W | 200Mesh |
| (1) | Indicator |
| I | Visual type *standard equipment |
| E | Electric contact type |
| D | Electric contact type(micro capacity) |
| (2) | Magnet |
| - | n/a |
| M | Attached |
| (3) | Companion flange |
| - | Weld type |
| P | Rc threaded type |
| Code | Fluid type |
| - | Mineral oil |
| F | Phosphate ester oil |
| G | Water glycol oil |
| Code | Inner diameter |
| 03A | 10A |
| 04A | 15A |
| 06A | 20A |
| 08A | 25A |
| 10A | 32A |
| 12A | 40A |
| 16A | 50A |
| 20B | 65A |
| 24B | 80A |
| 28A | 90A |
| 32A | 100A |
| Code | filtration |
| Wire gauze | |
| 60W | 60Mesh |
| 100W | 100Mesh |
| 150W | 150Mesh |
| 200W | 200Mesh |
| Code | Sealing parts set |
| SP |
For element replacement |
| SA | For overhaul |
| Code | Fluid type |
| - | Mineral oil |
| F | Phosphate ester oil |
| G | Water glycol oil |
| Code | Inner diameter |
| 03A | 10A |
| 04A | 15A |
| 06A | 20A |
| 08A | 25A |
| 10A | 32A |
| 12A | 40A |
| 16A | 50A |
| 20B | 65A |
| 24B | 80A |
| 28A | 90A |
| 32A | 100A |
*1 For fluids other than the above fluids. Please ask us for details.
Filter Model example:F-VN-12A-150W-I
Element Model example:P-F-VN-12A-150W
Seals Model example:SA-F-VN-12A
■ Model code of replacement element consists of two types: ”Individual code” and "Common code", however it represents same product.
”Individual code” :Used in drawings and nameplate.
Model example:P-F-VN-12A-150W
"Common code" :Used in vouchers and tag.
Model example:P-F-VN-10,12-150W
+81-3-6912-9922+81-3-6912-9922