Oil Filters List

COS-H

COS-H
Type

Duplex filter

Application

Duplex filter is used to continuously operated lublication system.

Features

・Element can be replaced without stopping operations.

・Welded structure duplex filter

・Several types of flange rating are selectable. (ANSI, JPI, JIS) 

Download

Specifiations

Item Standard Spec. Option
Corresponding fluid Mineral oil -
Maximum working pressure 0~2.0MPa -
Indicator n/a Select from visual type, electric contact type, and electric contact type (micro capacity)
Relief valve (Bypass) n/a -
Connection JIS 20K SOP, FF (Companion flange attached) Can select JIS, ANSI, JPI flange ratings other than those listed to the left
Magnet n/a Installation optional

ItemsModel

COS-H

Inner diameter

Code Inner diameter
04 15A
06 20A
08 25A
10 32A
12 40A
16 50A
20 65A
24 80A
28 90A
32 100A

Flow direction

Code Direction
A IN → OUT (C-Fiber,Paper,Wire gauze)
B OUT → IN (Notch wire)

Filtration

Code Filtration
C-Fiber
8C 8μm
25C 25μm
Paper
10U 10μm
20U*1 20μm
40U*1 40μm
Wire gauze
5UW 5μm
10UW 10μm
20UW 20μm
40UW 40μm
50UW 50μm
200W 200Mesh
150W 150Mesh
100W 100Mesh
60W 60Mesh
Notch wire
50UK 50μm
200K 200Mesh
150K 150Mesh
100K 100Mesh
60K 60Mesh

Option(1)(2)(3)(4)

(1) Change-over handle
- Standard position
R Opposite position
(2) Flange ratings *2
- JIS20K SOP,FF(SS400)
A ANSI150LB SO,RF(A105)
B ANSI300LB SO,RF(SFVC2A)
C JPI150LB SO,RF(A105)
E JPI300LB SO,RF(SFVC2A)
F JIS20K SOH,RF(S25C)
(3) Indicator
- Blind plug
I Visual type
E electric contact type
D electric contact type (micro capacity)
(4) Magnet
- n/a
M Attached

P

COS-H

Inner diameter

Code Inner diameter
04 15A
06 20A
08 25A
10 32A
12 40A
16 50A
20 65A
24 80A
28 90A
32 100A

Flow direction

Code Direction
A IN → OUT (C-Fiber,Paper,Wire gauze)
B OUT → IN (Notch wire)

Filtration

Code Filtration
C-Fiber
8C 8μm
25C 25μm
Paper
10U 10μm
20U*1 20μm
40U*1 40μm
Wire gauze
5UW 5μm
10UW 10μm
20UW 20μm
40UW 40μm
50UW 50μm
200W 200Mesh
150W 150Mesh
100W 100Mesh
60W 60Mesh
Notch wire
50UK 50μm
200K 200Mesh
150K 150Mesh
100K 100Mesh
60K 60Mesh

Set type*3

Code Sealing parts set
SP

For element

replacement

SA For overhaul

COS-H

Inner diameter

Code Inner diameter
04 15A
06 20A
08 25A
10 32A
12 40A
16 50A
20 65A
24 80A
28 90A
32 100A

Flow direction

Code Direction
A IN → OUT (C-Fiber,Paper,Wire gauze)
B OUT → IN (Notch wire)

Option (2)(3)

(2) Flange rating
- JIS20K SOP,FF(SS400)
A ANSI150LB SO,RF(A105)
B ANSI300LB SO,RF(SFVC2A)
C JPI150LB SO,RF(A105)
F JPI300LB SO,RF(SFVC2A)
H JIS20K SOH,RF(S25C)
(3) Indicator
- Blind plug
I Visual type
E Electric contact type
D Electric contact type (micro capacity)

*1 20U and 40U are not available for water glycol oil.

*2 In case of JS 20k SOP, FF: Different diameter companion frange is attached for innner diameter of 04, 08, 12, 20, 28. Moreover, only innner diameter of 06, 10, 16, 24,32 are available for other flange rating (companion flange is not included).

*3 Sealing parts set for element replacement (Code "SP") is for 1 filter. 2 sets are required for duplex filter assembly. 

Filter Model example:COS-H-16-A-10U-EM

Element Model example:P-COS-H-16-A-10U

Seals  Model example:SA-COS-H-16-A-E

Contact

Please login, and you will send selection request.