VM

We have decided to discontinue the production of product “VM model”.

For more information,Click here !

Case type suction filter

Application

This filter protects the hydraulic pump by preventing the circulation of line contamination from the reservoir tank. Especially, it is suitable for the changeable capacity type oil pressure pump

Features

  • A highly efficient exterior magnet is utilized for cleaning ease.
  • Signature case type suction filter model
  • The upper extraction type makes element replacement easy
  • The shape of the case prevents air accumulation within the case
  • PDF Drawing
  • CAD Drawing
  • Catalogue
  • Instruction manual
  • Spare Parts List

Specifications

Items  
Standard specifications Possible corresponding specifications / options, etc.
Corresponding fluid Mineral oil Phosphate ester oil, water glycol oil
Maximum working pressure -0.1∼0.5MPa -
Indicator n/a Visual type, Select from electric contact type, electric contact type (micro capacity)
Relief valve (Bypass) n/a Installation optional
Connection Weld flange type Can modify with Rc threaded flange type
Magnet Equipped Installation optional

Model

  • Model number
  • Element
  • Seals

Model example:F-VM-08-150W-MUK

 

Code Fluid type
- Mineral oil
F Phosphate ester oil
G Water glycol oil
 
Code Inner diameter
03 10A
04 15A
06 20A
08 25A
10 32A
12 40A
 
Code filtration
SUS Mesh
60W 60Mesh
100W 100Mesh
150W 150Mesh
200W 200Mesh
 
(1) Magnet
M standard equipment
(2) Indicator
- n/a
U Visual type
E Electric contact type
D Electric contact type(micro capacity)
(3) Relief valve (Bypass)
K n/a
V Attached
*1 For fluids other than the above fluids.
*2 For general oil-based fluid specifications and water glycol oil specifications, the filtering material and design may be differ even with the same filtration accuracy.

Model example:P-F-VM-08-150W

Code Fluid type
- Mineral oil
F Phosphate ester oil
G Water glycol oil
 
Code Inner diameter
03 10A
04 15A
06 20A
08 25A
10 32A
12 40A
 
Code filtration
SUS Mesh
60W 60Mesh
100W 100Mesh
150W 150Mesh
200W 200Mesh
*1 For fluids other than the above fluids.
*2 For general oil-based fluid specifications and water glycol oil specifications, the filtering material and design may be differ even with the same filtration accuracy.

Model example:SA-F-VM-08

 

Code Fluid type
- Mineral oil
F Phosphate ester oil
G Water glycol oil
 
Code Inner diameter
03 10A
04 15A
06 20A
08 25A
10 32A
12 40A
*1 For fluids other than the above fluids.
*2 For overhaul : all packings and o-rings used in oil filter housing