TRA

Return line filter

Application

The TRA is installed on the return line of the reservoir tank just before the reservoir tank to prevent contaminants from entering the tank.

Features

  • By using CFD(fluid numerical analysis), achieved low pressure drop and large flow rate.
    • Installed directly on top of a tank.
      • Newly added set element for high flow type.
        • Differential pressure indicator to the lineup.
        • PDF Drawing
        • CAD Drawing
        • Catalogue
        • Instruction manual

Specifications

Items  
Standard specifications Possible corresponding specifications / options, etc.
Corresponding fluid Mineral oil Phosphate ester oil, water glycol oil
Maximum working pressure 0`1MPa -
Indicator n/a Select from visual type, electric contact type, and electric contact type (micro capacity)
Relief valve (Bypass) n/a Installation optional
Connection Rc threaded type Can be modified with an optional weld flange type
Magnet - -

Model

  • Model number
  • Element
  • Seals

Model exampleFTRA-08-10UF-IVN

 

Code Fluid type
- Mineral oil
F Phosphate ester oil
G Water glycol oil
 
Code Inner diameter
06 Rc3/4 (20A)
08 Rc1 (25A)
 
Code Filtration
Micro-glass element
3C 3m
8C 8m
25C 25m
High flow cellulose
10UF 3 10m
20UF 3 20m
Cellulose
10U 10m
20U *3 20m
40U *3 40m
SUS Mesh
5UW 5m
10UW 10m
20UW 20m
40UW 40m
50UW 50m
200W 200Mesh
150W 150Mesh
100W 100Mesh
60W 60Mesh
 
(1) Indicator
- Plug
I Visual Type
E Electric contact type
D electric contact type(micro capacity)
(2) Relief valve (Bypass)
K -
V Attached
(3) Companion flange
- -
N With
*1 For fluids other than the above fluids.
*2 For general oil-based fluid specifications and water glycol oil specifications, the filtering material and design may be differ even with the same filtration accuracy.
*3 10UF AND 20UF AND 20U and 40U unsuitable for water-glycol based oils

Model exampleFP-TRA-08-10UF

Code Fluid type
- Mineral oil
F Phosphate ester oil
G Water glycol oil
 
Code Inner diameter
06 Rc3/4 (20A)
08 Rc1 (25A)
 
Code Filtration
Micro-glass element
3C 3m
8C 8m
25C 25m
High flow cellulose
10UF 3 10m
20UF 3 20m
Cellulose
10U 10m
20U *3 20m
40U *3 40m
SUS Mesh
5UW 5m
10UW 10m
20UW 20m
40UW 40m
50UW 50m
200W 200Mesh
150W 150Mesh
100W 100Mesh
60W 60Mesh
*1 For fluids other than the above fluids.
*2 For general oil-based fluid specifications and water glycol oil specifications, the filtering material and design may be differ even with the same filtration accuracy.
*3 20U and 40U unsuitable for water-glycol based oils

Model exampleFSA-TRA-08-N

 

Code Fluid type
- Mineral oil
F Phosphate ester oil
G Water glycol oil
 
Code Inner diameter
06 Rc3/4 (20A)
08 Rc1 (25A)
 
(3) Companion flange
- n/a
N Attached
*1 For fluids other than the above fluids.
*2 For overhaul : all packings and o-rings used in oil filter housing