Indication (operation)pressure |
|
| Compatible models |
Model number |
System |
Red indication start |
All red indication |
Remarks |
| VN |
ID-02 |
Manual reset/Visual type |
0.012MPa |
0.02MPa |
Standard options |
| ED-02 |
Automatic reset・electric contact type |
0.02MPa |
Visual signal DIN connector Code:IEC529(EN60529)IP65 |
| ED-02D |
Automatic reset・micro capacity electric contact type |
| |
| VM |
UG |
Visual type |
-100kPa〜0kPa |
Pressure gauge type (Secondary pressure detection) |
| TSF |
EG-03 |
Automatic reset・electric contact type |
0.03MPa |
Pressure switch type (Secondary pressure detection) DIN connector Code:IEC529(EN60529)IP65 |
| EG-03D |
Automatic reset・micro capacity electric contact type |
| |
| ISH |
U4-02 |
Manual reset/Visual type |
- |
0.02MPa |
Standard options |
| E4-02 |
Automatic reset・electric contact type |
0.02MPa |
DIN connector Code:IEC529(EN60529)IP65 |
| E4-02D |
Automatic reset・electric contact type |
| |
| |
|
|
Indication (operation)pressure |
|
| Compatible models |
Model number |
System |
Red indication start |
All red indication |
Remarks |
| 351/2 |
IA-3 |
Automatic reset/Visual type |
0.2MPa |
0.3MPa |
|
| UL,UM |
EA-3 |
Automatic reset・electric contact type |
0.3MPa |
Visual signal DIN connector Code:IEC529(EN60529)IP65 |
| TL |
EA-3D |
Automatic reset・micro capacity electric contact type |
| LCN |
| COS-L |
| COS-H |
| UR |
| 107 |
| *FP-1500A-1010 |
| |
| UH |
IF-3 |
Automatic reset/Visual type |
0.2MPa |
0.3MPa |
|
| TM |
IF-7 |
0.2MPa |
0.7MPa |
For high pressure elements |
| 3501/2 |
EF-3 |
Automatic reset・electric contact type |
0.3MPa |
Visual signal DIN connector Code:IEC529(EN60529)IP65 |
| SH |
EF-3D |
Automatic reset・micro capacity electric contact type |
| GM |
EF-7 |
Automatic reset・electric contact type |
0.7MPa |
For high pressure elements Visual signal DIN connector Code:IEC529(EN60529)IP65 |
| GF |
EF-7D |
Automatic reset・micro capacity electric contact type |
| 4201 |
| MVF |
| |
| |
|
|
Indication (operation)pressure |
|
| Compatible models |
Model number |
System |
Red indication start |
All red indication |
Remarks |
| GC |
IH-3 |
Automatic reset/Visual type |
0.2MPa |
0.3MPa |
|
| IH-7 |
Automatic reset/Visual type |
0.2MPa |
0.7MPa |
For high pressure elements |
| EH-3 |
Automatic reset・electric contact type |
0.3MPa |
Visual signal DIN connector Code:IEC529(EN60529)IP65 |
| EH-3D |
Automatic reset・micro capacity electric contact type |
| EH-7 |
Automatic reset・electric contact type |
0.7MPa |
For high pressure elements Visual signal DIN connector Code:IEC529(EN60529)IP65 |
| EH-7D |
Automatic reset・micro capacity electric contact type |
| |
| TRF |
UT-4 |
Visual type |
0-1.0MPa(Red indication 0.3MPa-) |
Pressure gauge type (Primary pressure detection) |
| - |
Automatic reset・electric contact type |
0.3MPa |
Pressure switch type (Primary pressure detection) |
| |
| TR |
UT-1 |
Visual type |
0MPa〜1MPa |
Pressure gauge type (TR type detects primary pressures only. The CF type detects primary and secondary pressures according to installation position) |
| CF |
| |
| FP-400Z |
UT-3 |
Visual type |
0-0.5MPa(Red indication 0.3MPa-) |
Pressure gauge type (Primary pressure detection) |